Bosch Heat Pumps

60 fault codes documented

5203

Alarm Outdoor sensor TL1 faulty

The Heat Pump has detected a fault with the outdoor temperature sensor (TL1). This alarm indicates that the sensor or its signal cable has failed, is missing, or has short-circuited after multiple warnings.

5206

Alarm Flow sensor T0 faulty

The Heat Pump has detected a fault with the primary flow sensor (T0). This alarm indicates that the sensor or its signal cable has either failed or short-circuited after multiple warnings.

5209

Alarm Z1 heat transfer fluid out sensor TC1 faulty

The Heat Pump has detected a fault with the heat transfer fluid outlet sensor (TC1) for zone 1. This alarm indicates the sensor or its signal cable has either failed or short-circuited after multiple warnings.

5212

Alarm Z2 heat transfer fluid out sensor TC1 faulty

The Heat Pump has detected a fault with the heat transfer fluid outlet sensor (TC1) for zone 2. This alarm indicates the sensor or its signal cable has either failed or short-circuited after multiple warnings.

5215

Alarm Z1 heat transfer fluid in sensor TC0 faulty

The Heat Pump has detected a fault with the heat transfer fluid inlet sensor (TC0) for zone 1. This alarm indicates the sensor or its signal cable has either failed or short-circuited after multiple warnings.

5218

Alarm Z2 heat transfer fluid in sensor TC0 faulty

The Heat Pump has detected a fault with the heat transfer fluid inlet sensor (TC0) for zone 2. This alarm occurs after multiple short circuit or failure warnings for sensor TC0 over a short period.

5236

Alarm Pool temperature sensor TP1 faulty

The Heat Pump has detected a fault with the pool temperature sensor (TP1). This alarm indicates the sensor or its signal cable has either failed or short-circuited after multiple warnings.

5239

Alarm Z1 hot water sensor TW1 faulty

The Heat Pump has detected a fault with the hot water sensor (TW1) for zone 1. This alarm indicates a failure or short circuit in the sensor or its signal cable after multiple warnings.

5246

Alarm Z1 electric cassette E2 tripped overheat protection / pressure switch

The electric cassette for zone 1 has triggered its overheat protection or the system pressure switch has indicated low pressure (below 0.5 bar) in the air module. This prevents damage to the unit.

5247

Alarm Z2 electric cassette E2 tripped overheat protection / pressure switch

The electric cassette for zone 2 has triggered its overheat protection or the system pressure switch has indicated low pressure (below 0.5 bar) in the air module. This prevents damage to the unit.

5249

Warning Heat Pump Z1 not working optimally (high heat curve/hot water setting)

Your Heat Pump for zone 1 is reporting that it cannot operate at optimal efficiency because its heat curve or hot water temperature settings are too high, leading to increased energy consumption.

5251

Warning Heat Pump Z2 not working optimally (high heat curve/hot water setting)

Your Heat Pump for zone 2 is reporting that it cannot operate at optimal efficiency because its heat curve or hot water temperature settings are too high, leading to increased energy consumption.

5252

Warning Heat Pump Z1 limited by low heating medium flow (check filter)

Your Heat Pump for zone 1 is operating with reduced performance due to insufficient heat transfer fluid flow. This can happen if the temperature difference (delta) is too high in heating or cooling mode.

5266

Alarm Heat Pump board Z1 disconnected

The Heat Pump control board for zone 1 has lost communication with the indoor unit (tower). This alarm is triggered after multiple warnings or a prolonged communication failure via the CAN bus.

5299

Alarm 5299 — Heat Pump Z1 pressure too high

The pressure in Heat Pump Z1, monitored by sensor JR1, has registered as too high (above 67°C or 44 bar G) three times within two hours, leading to an alarm.

5353

5353 - Bosch Heat Pump Z2 asynchronous drive on compressor alarm

This alarm indicates that the compressor motor in Bosch Heat Pump zone 2 is not running synchronously. It triggers after 3 warnings within 3 hours, or if a warning is active for 30 minutes. The system may reset after 4 minutes if the cause is resolved.

5355

5355 - Bosch Heat Pump Z1 compressor overcurrent alarm

This alarm signifies that the compressor in Bosch Heat Pump zone 1 is drawing too much current. It activates after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5357

5357 - Bosch Heat Pump Z2 compressor overcurrent alarm

This alarm indicates that the compressor in Bosch Heat Pump zone 2 is drawing excessive current. It triggers after 3 warnings within 3 hours, or if a warning is active for 30 minutes.

5361

5361 - Bosch Heat Pump Z2 PFC overcurrent on compressor driver alarm

This alarm indicates an overcurrent issue in the Power Factor Correction (PFC) part of the compressor driver in Bosch Heat Pump zone 2. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5362

5362 - Bosch Heat Pump Z1 overvoltage information message

This information message appears if the DC bus voltage in Bosch Heat Pump zone 1 exceeds 440 V for more than 30 seconds. The message typically resets after 4 minutes if the DC bus voltage drops below 380 V.

5367

5367 - Bosch Heat Pump Z1 low overheating alarm

This alarm indicates that Bosch Heat Pump zone 1 is experiencing conditions of low overheating. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5369

5369 - Bosch Heat Pump Z2 low overheating alarm

This alarm indicates that Bosch Heat Pump zone 2 is experiencing conditions of low overheating. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5377

5377 - Bosch Heat Pump Z2 freeze protection of condenser alarm

This alarm indicates that the condenser in Bosch Heat Pump zone 2 is at risk of freezing. It triggers if the temperature sensor TC3 is below 5°C. The alarm resets when TC3 and TC1 are both above 7°C. This alarm activates after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5378

5378 - Bosch Heat Pump Z1 failed defrosting warning

This warning indicates that Bosch Heat Pump zone 1 has failed its defrosting cycle. It triggers if the condenser temperature (TR24) is below 25°C or pressure sensor (PH1) is below 30°C after 800 seconds in defrosting. This warning activates after 3 occurrences in 3 hours, or if conditions are active for 30 minutes.

5380

Warning Heat Pump Z2 failed defrosting

This warning indicates that Heat Pump Z2 has failed to complete its defrosting cycle. It occurs if specific temperature or pressure conditions are not met during defrosting, triggering after 3 failures in 3 hours, or if conditions are active for 30 minutes.

5387

Alarm Heat Pump Z1 compressor driver is too hot

This alarm indicates that the compressor driver for Heat Pump Z1 is overheating. This happens if the internal temperature sensor in the inverter's PFC module exceeds 80°C for 10 seconds.

5389

Alarm Heat Pump Z2 compressor driver is too hot

This alarm indicates that the compressor driver for Heat Pump Z2 is overheating. This happens if the internal temperature sensor in the inverter's PFC module exceeds 80°C for 10 seconds.

5395

Alarm Heat Pump Z1 Internal compressor driver fault 1

This alarm indicates an internal fault with the compressor driver in Heat Pump Z1. It triggers after 3 warnings within 3 hours, or if a warning remains active for 30 minutes.

5397

Alarm Heat Pump Z2 Internal compressor driver fault 1

This alarm indicates an internal fault with the compressor driver in Heat Pump Z2. It triggers after 3 warnings within 3 hours, or if a warning remains active for 30 minutes.

5410

Alarm Heat Pump Z1 air intake temperature sensor TL2 faulty

This alarm indicates a fault with the air intake temperature sensor TL2 in Heat Pump Z1, possibly due to a failure or short circuit. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5413

Alarm Heat Pump Z1 air intake temperature sensor TL2 faulty

This alarm indicates a fault with the air intake temperature sensor TL2 in Heat Pump Z1, possibly due to a failure or short circuit. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5416

Alarm Heat Pump Z1 fluid line in heating mode sensor TR3 faulty

This alarm indicates a fault with the fluid line sensor TR3 for Heat Pump Z1 while in heating mode. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5419

Alarm Heat Pump Z2 fluid line in heating mode sensor TR3 faulty

This alarm indicates a fault with the fluid line sensor TR3 for Heat Pump Z2 while in heating mode. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5422

Alarm Heat Pump Z1 fluid line in cooling mode sensor TR4 faulty

This alarm indicates a fault with the fluid line sensor TR4 for Heat Pump Z1 while in cooling mode. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5425

Alarm Heat Pump Z2 fluid line in cooling mode sensor TR4 faulty

This alarm indicates a fault with the fluid line sensor TR4 for Heat Pump Z2 while in cooling mode. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5428

Alarm Heat Pump Z1 suction gas sensor TR5 faulty

This alarm indicates a fault with the suction gas sensor TR5 for Heat Pump Z1. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5431

Alarm Heat Pump Z2 suction gas sensor TR5 faulty

This alarm indicates a fault with the suction gas sensor TR5 for Heat Pump Z2. This could be due to a sensor failure or a short circuit in the cable. It triggers after 3 faults in 2 hours, or 15 minutes of continuous failure or short circuit.

5434

Alarm Heat Pump Z1 pressure sensor low pressure JR0 faulty

This alarm indicates a fault with the low-pressure sensor JR0 for Heat Pump Z1. This could be due to a wiring issue or a defective sensor. It triggers after 3 faults in 2 hours, or 15 minutes of constant failure.

5437

Alarm Heat Pump Z2 pressure sensor low pressure JR0 faulty

This alarm indicates a fault with the low-pressure sensor JR0 for Heat Pump Z2. This could be due to a wiring issue or a defective sensor. It triggers after 3 faults in 2 hours, or 15 minutes of constant failure.

5440

Alarm Heat Pump Z1 pressure sensor high pressure JR1 faulty

This alarm indicates a fault with the high-pressure sensor JR1 for Heat Pump Z1. This could be due to a wiring issue or a defective sensor. It triggers after 3 faults in 2 hours, or 15 minutes of constant failure.

5512

5512 - Bosch Heat Pump Z1 condensing temperature outside envelope warning

This warning indicates that the condensing temperature in Bosch Heat Pump zone 1 is outside its highest permitted range. It triggers if the temperature on sensor PH1 is above the highest permitted actual envelope for longer than 30 seconds.

5513

5513 - Bosch Heat Pump Z1 condensation too high alarm

This alarm indicates that condensation levels in Bosch Heat Pump zone 1 are too high. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5514

5514 - Bosch Heat Pump Z1 low pressure warning JR0

This warning indicates low pressure (JR0) in Bosch Heat Pump zone 1. It triggers if sensor PL1 is below the lowest permitted actual envelope (-27°C) for longer than 30 seconds.

5515

5515 - Bosch Heat Pump Z1 low evaporation JR0 alarm

This alarm indicates low evaporation pressure (JR0) in Bosch Heat Pump zone 1. It activates after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5517

5517 - Bosch Heat Pump Z2 condensation too high alarm

This alarm indicates that condensation levels in Bosch Heat Pump zone 2 are too high. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5518

5518 - Bosch Heat Pump Z2 condensing temperature outside envelope warning

This warning indicates that the condensing temperature in Bosch Heat Pump zone 2 is outside its highest permitted range. It triggers if the temperature on sensor PH1 is above the highest permitted actual envelope for longer than 30 seconds.

5520

5520 - Bosch Heat Pump Z2 low pressure warning JR0

This warning indicates low pressure (JR0) in Bosch Heat Pump zone 2. It triggers if sensor PL1 is below the lowest permitted actual envelope (-27°C) for longer than 30 seconds.

5521

5521 - Bosch Heat Pump Z2 low evaporation JR0 alarm

This alarm indicates low evaporation pressure (JR0) in Bosch Heat Pump zone 2. It activates after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5524

5524 - Bosch Heat Pump Z1 PFC overcurrent on compressor driver alarm

This alarm indicates an overcurrent issue in the Power Factor Correction (PFC) part of the compressor driver in Bosch Heat Pump zone 1. It activates after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

5526

5526 - Bosch Heat Pump Z2 defrosting system alarm: Clean outdoor part

This alarm indicates that the defrosting cycle for Bosch Heat Pump zone 2 has exceeded its normal time or required too many attempts. It triggers if the timer for defrosting exceeds 800 seconds 3 times, or if 3 defrostings are needed in minimum time for heat production.

5527

5527 - Bosch Heat Pump Z1 too much refrigerant alarm

This alarm indicates that there is too much refrigerant in Bosch Heat Pump zone 1. It triggers if sensor PH1 is more than 5°C higher than TC3, and undercooling is greater than the set point, with both conditions met for longer than 5 minutes during hot water production.

5528

5528 - Bosch Heat Pump Z2 compressor sensor TR1 failure warning

This warning indicates a failure of compressor sensor TR1 in Bosch Heat Pump zone 2. It triggers after 3 faults (reading >364 kOhm) in 2 hours.

5529

5529 - Bosch Heat Pump Z2 compressor sensor TR1 short circuit warning

This warning indicates that compressor sensor TR1 in Bosch Heat Pump zone 2 has a short circuit. It triggers after 3 faults (reading >350 kOhm) in 2 hours.

5530

5530 - Bosch Heat Pump Z2 compressor sensor TR1 faulty alarm

This alarm indicates a fault, failure, or short circuit with compressor sensor TR1 in Bosch Heat Pump zone 2. It triggers after 3 faults in 3 hours, or 15 minutes of failure/short circuit on the sensor.

5531

5531 - Bosch Heat Pump Z1 compressor sensor TR1 failure warning

This warning indicates a failure of compressor sensor TR1 in Bosch Heat Pump zone 1. It triggers after 3 faults (reading >170 kOhm) in 2 hours.

5532

5532 - Bosch Heat Pump Z1 compressor sensor TR1 short circuited warning

This warning indicates that compressor sensor TR1 in Bosch Heat Pump zone 1 has a short circuit. It triggers after 3 faults (reading >350 kOhm) in 2 hours.

5533

5533 - Bosch Heat Pump Z1 compressor sensor TR1 faulty alarm

This alarm indicates a fault, failure, or short circuit with compressor sensor TR1 in Bosch Heat Pump zone 1. It triggers after 3 faults in 3 hours, or 15 minutes of failure/short circuit on the sensor.

Air in system

Gurgling noises or cold spots — Air in heating system

Air trapped within the heat transfer or heating system can cause gurgling sounds, cold spots in radiators, and reduced heating efficiency.

Filter blocked

Reduced efficiency — System filter blocked with dirt

The system filter or filter ball (SC1) is obstructed by dirt, which can significantly reduce the efficiency of your Heat Pump and heating system.

Poor circulation

Uneven heating/cooling — Poor circulation in heating system

The flow of heat transfer fluid in your heating system is inadequate, leading to poor and uneven heating or cooling performance from the Heat Pump.