5518

5518 - Bosch Heat Pump Z2 condensing temperature outside envelope warning

Bosch · Heat Pumps

What does 5518 mean?

This warning indicates that the condensing temperature in Bosch Heat Pump zone 2 is outside its highest permitted range. It triggers if the temperature on sensor PH1 is above the highest permitted actual envelope for longer than 30 seconds.

Common Causes

  • Evaporation temperature is too low in relation to the condensing temperature, likely due to low outdoor temperature.
  • Incorrect flow rate (too high or too low delta) in the heating system.
  • Blocked or low air flow to the air heat exchanger on the Heat Pump.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the current outdoor temperature; extremely low temperatures can affect the system's performance.

  2. 2

    Review your heating system's flow and temperature settings and adjust them if necessary to ensure proper operation.

  3. 3

    Ensure adequate air flow over the air heat exchanger on the Heat Pump by clearing any obstructions like leaves or debris.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026