33-55

Code 33-55 Compressor Low Discharge Lockout — System locked out due to repeated low discharge pressure

Carrier · Air Conditioners & Heat Pumps

What does 33-55 mean?

This lockout occurs after 6 instances of 'Code 33-15 Compressor Low Discharge Shutdown' within a 2-hour period. The system will be locked out for 2 hours.

Common Causes

  • Repeated occurrences of low discharge pressure.
  • Malfunctioning reversing valve.
  • Low refrigerant charge.
  • Missing or stuck TXV/EXV (Thermostatic/Electronic Expansion Valve).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Wait for the 2-hour lockout period to expire.

  2. 2

    Address the underlying causes of Code 33-15 (e.g., check reversing valve, refrigerant charge, TXV/EXV).

  3. 3

    If the problem persists, contact a qualified technician for further diagnosis and repair.