38-13

Code 38-13 VFD Compressor Fault - Start Fail — Compressor failed to start

Carrier · Air Conditioners & Heat Pumps

What does 38-13 mean?

The VFD (Variable Frequency Drive) has detected additional compressor starting failures. While active, the unit opens the PEV (Pressure Equalization Valve) to equalize pressure and attempt retries. Three consecutive occurrences lead to a lockout (Code 38-53).

Common Causes

  • Loose compressor wiring connections.
  • Damaged compressor wiring.
  • Incorrect compressor wire order.
  • Compressor damage.
  • High pressure differential across the compressor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check all compressor wiring connections to ensure they are secure.

  2. 2

    Inspect compressor wires for any damage.

  3. 3

    Verify the compressor wire order against the wiring diagram (technician step).

  4. 4

    If malfunctions continue and pressure differential across compressor is confirmed to be <40psi, replace the compressor (technician step).