31

High Pressure Switch Open Event 31

Carrier · Heat Pumps

What does 31 mean?

The high pressure switch has opened, indicating a high pressure event within the system. The system will attempt to self-mitigate. Persistent high pressure conditions will lead to a lockout (Error Code 84). The system will reset after 15 minutes.

Common Causes

  • High Pressure Event

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    The system will attempt to self-mitigate the high pressure condition over 15 minutes.

  2. 2

    Check the refrigerant charge level in the system.

  3. 3

    Inspect the outdoor fan operation and the outdoor coil for any airflow restrictions, especially in cooling mode.

  4. 4

    Check the indoor airflow for restrictions if the unit is in heating mode.