58

Lost Inverter Communications Event 58

Carrier · Heat Pumps

What does 58 mean?

Communication has been lost between the outdoor unit (ODU) circuit board and the inverter. The system will attempt to self-mitigate. Persistent conditions will lead to lockout (Error Code 48). The system will reset after 10 minutes.

Common Causes

  • Communication lost between ODU circuit board and inverter

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the inverter harness connections between the ODU circuit board and the inverter for secure fit.

  2. 2

    Ensure there are no loose wires, stripped wires, or shorts in the communication wiring.

  3. 3

    The system will attempt to self-mitigate and recover within 10 minutes.

  4. 4

    If the issue persists or leads to Error Code 48, refer to the troubleshooting steps for 'Lost Inverter Communications Lockout'.