Red 7 Flashes, Green 3 Flashes

Red 7 Flashes, Green 3 Flashes (Single System) — High Pressure

Fujitsu · Air Conditioners

What does Red 7 Flashes, Green 3 Flashes mean?

The red LED flashes seven times and the green LED flashes three times on the indoor unit. This indicates that the refrigeration system is operating under excessively high pressure.

Common Causes

  • Overcharged refrigerant system.
  • Dirty outdoor heat exchanger (condenser coil).
  • Outdoor fan motor malfunction, leading to poor heat rejection.
  • Restricted airflow or blockages in the refrigeration lines.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the unit immediately at the circuit breaker to prevent damage.

  2. 2

    Ensure the outdoor unit's coil is clean and free of debris, which can impede airflow.

  3. 3

    Check that nothing is obstructing the outdoor fan blades.

  4. 4

    This fault typically requires a professional HVAC technician to diagnose and rectify refrigerant levels or system blockages.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

AFM Filter Error (AUY, ABY & AWY)Red Blinks, Green 12 Pulses, Yellow Off (AUY, ABY & AWY) — Active Filter Module ErrorAir Sensor Closed (AUY, ABY & AWY)Red 2 Pulses, Green Blinks, Yellow Blinks (AUY, ABY & AWY) — Air Sensor Closed Circuit (Short)Air Sensor Open (AUY, ABY & AWY)Red 2 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Air Sensor Open Circuit