Fujitsu Air Conditioners

60 fault codes documented

AFM Filter Error (AUY, ABY & AWY)

Red Blinks, Green 12 Pulses, Yellow Off (AUY, ABY & AWY) — Active Filter Module Error

The red LED blinks, the green LED shows 12 pulses, and the yellow LED is off. This indicates an error with the Active Filter Module (AFM), which is part of the power electronics.

Air Sensor Closed (AUY, ABY & AWY)

Red 2 Pulses, Green Blinks, Yellow Blinks (AUY, ABY & AWY) — Air Sensor Closed Circuit (Short)

The red LED shows 2 pulses, the green LED blinks, and the yellow LED blinks. This indicates a closed circuit (short circuit) condition in the air temperature sensor, which means the sensor is incorrectly connected or damaged.

Air Sensor Open (AUY, ABY & AWY)

Red 2 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Air Sensor Open Circuit

The red LED shows 2 pulses, the green LED blinks, and the yellow LED is off. This indicates an open circuit condition in the air temperature sensor, meaning the sensor is not connected or faulty.

CT Error (AUY, ABY & AWY)

Red Blinks, Green 11 Pulses, Yellow Off (AUY, ABY & AWY) — CT Error (Current Transformer)

The red LED blinks, the green LED shows 11 pulses, and the yellow LED is off. This indicates an error with the Current Transformer (CT), which measures the current flowing through the unit.

Communication Error (AUY, ABY & AWY)

Red 5 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Communication Error

The red LED shows 5 pulses, the green LED blinks, and the yellow LED is off. This indicates a general communication error between the indoor and outdoor units.

Compressor Error (AUY, ABY & AWY)

Red Blinks, Green 13 Pulses, Yellow Off (AUY, ABY & AWY) — Compressor Error

The red LED blinks, the green LED shows 13 pulses, and the yellow LED is off. This indicates a general error with the compressor in the outdoor unit, a critical component of the refrigeration cycle.

Drain Problem (AUY, ABY & AWY)

Red 4 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Drain Problem

The red LED shows 4 pulses, the green LED blinks, and the yellow LED is off. This indicates a problem with the unit's condensate drainage, likely due to a high water level.

E:0

E:0 — Indoor Unit to Remote Control Communication Failure

The wired remote control displays 'E:0' (after 'EE:EE' interrogation). This indicates a communication error between the indoor unit and its wired remote controller.

E:01

E:01 — Indoor Unit to Outdoor Unit Communication Failure

The wired remote control displays 'E:01' (after 'EE:EE' interrogation). This indicates a communication error between the indoor and outdoor units of the air conditioning system.

High Discharge or Compressor Temp (AUY, ABY & AWY)

Red Blinks, Green 7 Pulses, Yellow Off (AUY, ABY & AWY) — High Discharge or Compressor Temperature

The red LED blinks, the green LED shows 7 pulses, and the yellow LED is off. This indicates that either the compressor discharge temperature or the compressor's internal temperature is too high.

High Pressure (AUY, ABY & AWY)

Red Blinks, Green 6 Pulses, Yellow Off (AUY, ABY & AWY) — High Pressure

The red LED blinks, the green LED shows 6 pulses, and the yellow LED is off. This indicates that the air conditioning system is detecting excessively high pressure in the refrigerant circuit.

ID PCB Fail (AUY, ABY & AWY)

Red Blinks, Green Blinks, Yellow Off (AUY, ABY & AWY) — Indoor PCB Failure

The red and green LEDs blink, while the yellow LED is off. This indicates a failure of the Printed Circuit Board (PCB) in the indoor unit.

IPM Error (AUY, ABY & AWY)

Red Blinks, Green 10 Pulses, Yellow Off (AUY, ABY & AWY) — IPM Error

The red LED blinks, the green LED shows 10 pulses, and the yellow LED is off. This indicates an error with the Intelligent Power Module (IPM), which controls the compressor's inverter.

Indoor Fan Failure (AUY, ABY & AWY)

Red 6 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Indoor Fan Failure

The red LED shows 6 pulses, the green LED blinks, and the yellow LED is off. This indicates a failure of the indoor unit's fan motor.

OD Fan Motor Fail (AUY, ABY & AWY)

Red Blinks, Green 14 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Fan Motor Failure

The red LED blinks, the green LED shows 14 pulses, and the yellow LED is off. This indicates a failure of the outdoor unit's fan motor.

OD PCB Fail (AUY, ABY & AWY)

Red Blinks, Green Blinks, Yellow Blinks (AUY, ABY & AWY) — Outdoor PCB Failure

All three LEDs (Red, Green, Yellow) are blinking. This indicates a failure of the Printed Circuit Board (PCB) in the outdoor unit.

OD PCB or Wiring Error (AUY, ABY & AWY)

Red 5 Pulses, Green Blinks, Yellow Blinks (AUY, ABY & AWY) — Outdoor PCB or Wiring Error

The red LED shows 5 pulses, the green LED blinks, and the yellow LED blinks. This indicates a problem specifically with the outdoor unit's PCB or its associated wiring.

OD Power Connection Failure (AUY, ABY & AWY)

Red Blinks, Green 2 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Power Connection Failure

The red LED blinks, the green LED shows 2 pulses, and the yellow LED is off. This indicates a problem with the power connection to the outdoor unit.

OD Unit Air Sensor Fail (AUY, ABY & AWY)

Red Blinks, Green 4 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Unit Air Sensor Failure

The red LED blinks, the green LED shows 4 pulses, and the yellow LED is off. This indicates a failure of the outdoor ambient air temperature sensor.

OD Unit Air Sensor Short (AUY, ABY & AWY)

Red Blinks, Green 4 Pulses, Yellow Blinks (AUY, ABY & AWY) — Outdoor Unit Air Sensor Short Circuit

The red LED blinks, the green LED shows 4 pulses, and the yellow LED blinks. This indicates a short circuit in the outdoor ambient air temperature sensor or its wiring.

OD Unit Compressor Temp Sensor (AUY, ABY & AWY)

Red Blinks, Green 9 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Unit Compressor Temperature Sensor Failure

The red LED blinks, the green LED shows 9 pulses, and the yellow LED is off. This indicates a failure of the temperature sensor specifically for the outdoor unit's compressor.

OD Unit Disch Sensor Fail (AUY, ABY & AWY)

Red Blinks, Green 5 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Unit Discharge Sensor Failure

The red LED blinks, the green LED shows 5 pulses, and the yellow LED is off. This indicates a failure of the outdoor unit's discharge temperature sensor.

OD Unit Disch Sensor Short (AUY, ABY & AWY)

Red Blinks, Green 5 Pulses, Yellow Blinks (AUY, ABY & AWY) — Outdoor Unit Discharge Sensor Short Circuit

The red LED blinks, the green LED shows 5 pulses, and the yellow LED blinks. This indicates a short circuit in the outdoor unit's discharge temperature sensor or its wiring.

OD Unit Pipe Sensor Fail (AUY, ABY & AWY)

Red Blinks, Green 3 Pulses, Yellow Off (AUY, ABY & AWY) — Outdoor Unit Pipe Sensor Failure

The red LED blinks, the green LED shows 3 pulses, and the yellow LED is off. This indicates a failure of the temperature sensor on the outdoor unit's refrigerant pipe.

Pipe Sensor Closed (AUY, ABY & AWY)

Red 3 Pulses, Green Blinks, Yellow Blinks (AUY, ABY & AWY) — Pipe Sensor Closed Circuit (Short)

The red LED shows 3 pulses, the green LED blinks, and the yellow LED blinks. This indicates a closed circuit (short circuit) condition in the pipe temperature sensor, due to incorrect wiring or sensor damage.

Pipe Sensor Open (AUY, ABY & AWY)

Red 3 Pulses, Green Blinks, Yellow Off (AUY, ABY & AWY) — Pipe Sensor Open Circuit

The red LED shows 3 pulses, the green LED blinks, and the yellow LED is off. This indicates an open circuit condition in the pipe temperature sensor, meaning the sensor is either disconnected or faulty.

Red 2 Flashes, Green 2 Flashes

Red 2 Flashes, Green 2 Flashes (Single System) — Indoor Air Sensor Failure

Both the red and green LED lights on the indoor unit flash two times simultaneously. This signals a fault with the indoor air temperature sensor, which measures the room temperature.

Red 2 Flashes, Green 3 Flashes

Red 2 Flashes, Green 3 Flashes (Single System) — Indoor Pipe Sensor Failure

The red LED flashes two times and the green LED flashes three times on the indoor unit. This indicates an issue with the indoor pipe sensor, which monitors the temperature of the refrigerant pipe.

Red 2 Flashes, Green 4 Flashes

Red 2 Flashes, Green 4 Flashes (Single System) — Indoor Heat Exchanger Sensor Error

The red LED flashes two times and the green LED flashes four times on the indoor unit. This error indicates a problem with the sensor located on the indoor heat exchanger.

Red 2 Flashes, Green 6 Flashes

Red 2 Flashes, Green 6 Flashes (Single System) — Float Switch Operated (Drain Problem)

The red LED flashes two times and the green LED flashes six times on the indoor unit. This indicates that the float switch has been activated, typically due to a high water level in the drain pan.

Red 3 Flashes, Green 2 Flashes

Red 3 Flashes, Green 2 Flashes (Single System) — Outdoor Discharge Sensor Failure

The red LED flashes three times and the green LED flashes two times on the indoor unit. This indicates a failure with the outdoor unit's discharge temperature sensor.

Red 3 Flashes, Green 3 Flashes

Red 3 Flashes, Green 3 Flashes (Single System) — Outdoor Pipe Sensor Failure

Both the red and green LED lights on the indoor unit flash three times simultaneously. This indicates a problem with the outdoor unit's pipe temperature sensor.

Red 3 Flashes, Green 4 Flashes

Red 3 Flashes, Green 4 Flashes (Single System) — Outdoor Air Sensor Failure

The red LED flashes three times and the green LED flashes four times on the indoor unit. This indicates a fault with the outdoor ambient air temperature sensor.

Red 3 Flashes, Green 7 Flashes

Red 3 Flashes, Green 7 Flashes (Single System) — Heatsink Sensor Error

The red LED flashes three times and the green LED flashes seven times on the indoor unit. This indicates an error with the heatsink temperature sensor, typically located in the outdoor unit's inverter section.

Red 3 Flashes, Green 8 Flashes

Red 3 Flashes, Green 8 Flashes (Single System) — Compressor Temperature Sensor Failure

The red LED flashes three times and the green LED flashes eight times on the indoor unit. This signals a failure with the compressor temperature sensor in the outdoor unit.

Red 4 Flashes, Green 2 Flashes

Red 4 Flashes, Green 2 Flashes (Single System) — Forced Auto Switch Welded

The red LED flashes four times and the green LED flashes two times on the indoor unit. This indicates that the forced auto switch (manual operation switch) is stuck in the 'on' or 'welded' position.

Red 4 Flashes, Green 3 Flashes

Red 4 Flashes, Green 3 Flashes (Single System) — Main Relay Welded

The red LED flashes four times and the green LED flashes three times on the indoor unit. This indicates a problem with the main relay, suggesting it might be stuck in a closed or 'welded' position.

Red 4 Flashes, Green 4 Flashes

Red 4 Flashes, Green 4 Flashes (Single System) — Power Failure

Both the red and green LED lights on the indoor unit flash four times simultaneously. This indicates a power supply issue to the unit.

Red 4 Flashes, Green 7 Flashes

Red 4 Flashes, Green 7 Flashes (Single System) — VDD Permanent Stop Protection

The red LED flashes four times and the green LED flashes seven times on the indoor unit. This indicates that the VDD (Voltage Dependent Detector) protection has permanently stopped the unit, likely due to a severe voltage irregularity.

Red 4 Flashes, Green 8 Flashes

Red 4 Flashes, Green 8 Flashes (Single System) — Reverse VDD Permanent Stop

The red LED flashes four times and the green LED flashes eight times on the indoor unit. This indicates a permanent shutdown due to a reverse VDD (Voltage Dependent Detector) protection, possibly related to incorrect voltage phasing or severe power fluctuations.

Red 5 Flashes, Green 2 Flashes

Red 5 Flashes, Green 2 Flashes (Single System) — IPM Protection

The red LED flashes five times and the green LED flashes two times on the indoor unit. This indicates that the Intelligent Power Module (IPM) protection circuit has activated, usually due to an internal electrical fault or stress.

Red 5 Flashes, Green 3 Flashes

Red 5 Flashes, Green 3 Flashes (Single System) — CT Abnormal (Current Transformer Abnormal)

The red LED flashes five times and the green LED flashes three times on the indoor unit. This indicates an abnormal reading from the Current Transformer (CT), suggesting an issue with current measurement.

Red 5 Flashes, Green 5 Flashes

Red 5 Flashes, Green 5 Flashes (Single System) — Compressor Failure

Both the red and green LED lights on the indoor unit flash five times simultaneously. This is a critical error indicating a failure or malfunction of the compressor in the outdoor unit.

Red 5 Flashes, Green 6 Flashes

Red 5 Flashes, Green 6 Flashes (Single System) — Outdoor Fan Failure

The red LED flashes five times and the green LED flashes six times on the indoor unit. This indicates a problem with the outdoor unit's fan motor.

Red 6 Flashes, Green 2 Flashes

Red 6 Flashes, Green 2 Flashes (Single System) — Indoor Fan Motor Locked

The red LED flashes six times and the green LED flashes two times on the indoor unit. This indicates that the indoor fan motor is locked or unable to rotate freely.

Red 6 Flashes, Green 3 Flashes

Red 6 Flashes, Green 3 Flashes (Single System) — Indoor Fan Motor Rotation Error

The red LED flashes six times and the green LED flashes three times on the indoor unit. This indicates an error with the rotation of the indoor fan motor, meaning it's not spinning at the correct speed or not at all.

Red 7 Flashes, Green 2 Flashes

Red 7 Flashes, Green 2 Flashes (Single System) — High Discharge Temperature

The red LED flashes seven times and the green LED flashes two times on the indoor unit. This indicates that the discharge temperature of the compressor is excessively high.

Red 7 Flashes, Green 3 Flashes

Red 7 Flashes, Green 3 Flashes (Single System) — High Pressure

The red LED flashes seven times and the green LED flashes three times on the indoor unit. This indicates that the refrigeration system is operating under excessively high pressure.

Red 7 Flashes, Green 4 Flashes

Red 7 Flashes, Green 4 Flashes (Single System) — 4-Way Valve Abnormal

The red LED flashes seven times and the green LED flashes four times on the indoor unit. This indicates an abnormality with the 4-way valve, which controls the direction of refrigerant flow for heating and cooling modes.

Red 7 Flashes, Green 5 Flashes

Red 7 Flashes, Green 5 Flashes (Single System) — Pressure Switch Failure

The red LED flashes seven times and the green LED flashes five times on the indoor unit. This indicates a failure or abnormal reading from the pressure switch, which monitors refrigerant pressure.

Red 7 Flashes, Green 6 Flashes

Red 7 Flashes, Green 6 Flashes (Single System) — Compressor Temperature Error

The red LED flashes seven times and the green LED flashes six times on the indoor unit. This indicates an error related to the compressor's operating temperature, which is either too high or an incorrect reading.

Red 8 Flashes, Green 2 Flashes

Red 8 Flashes, Green 2 Flashes (Single System) — Active Filter AFM Fail 1st Time

The red LED flashes eight times and the green LED flashes two times on the indoor unit. This indicates the first occurrence of a failure in the Active Filter Module (AFM).

Red 8 Flashes, Green 3 Flashes

Red 8 Flashes, Green 3 Flashes (Single System) — Active Filter AFM Fail 2nd Time

The red LED flashes eight times and the green LED flashes three times on the indoor unit. This indicates a second, more persistent failure in the Active Filter Module (AFM).

Red 8 Flashes, Green 4 Flashes

Red 8 Flashes, Green 4 Flashes (Single System) — PFC Circuit Error

The red LED flashes eight times and the green LED flashes four times on the indoor unit. This indicates an error in the Power Factor Correction (PFC) circuit, which helps ensure efficient power usage.

Red Blinking, Green Blinking

Red Blinking, Green Blinking (Single System) — PCB Failure

Both the red and green LED lights on the indoor unit are blinking simultaneously. This typically indicates a failure of the main printed circuit board (PCB) within the indoor unit.

Red Off, Green 2 Flashes

Red Off, Green 2 Flashes (Single System) — Reverse Communication Failure at Startup

The green LED light on the indoor unit flashes two times while the red LED is off. This indicates that the reverse communication between the indoor and outdoor units failed when the system first started up.

Red Off, Green 3 Flashes

Red Off, Green 3 Flashes (Single System) — Reverse Communication Failure In Use

The green LED light on the indoor unit flashes three times while the red LED is off. This indicates a failure in the reverse communication between the indoor and outdoor units during normal operation.

Red Off, Green 4 Flashes

Red Off, Green 4 Flashes (Single System) — Forward Communication Failure at Startup

The green LED light on the indoor unit flashes four times while the red LED is off. This indicates that the forward communication between the indoor and outdoor units failed when the system started.

Red Off, Green 5 Flashes

Red Off, Green 5 Flashes (Single System) — Forward Communication Failure In Use

The green LED light on the indoor unit flashes five times while the red LED is off. This indicates a failure in the forward communication between the indoor and outdoor units during ongoing operation.

Red Off, Green 8 Flashes

Red Off, Green 8 Flashes (Single System) — Wired Remote Control Failure

The green LED light on the indoor unit flashes eight times while the red LED is off. This indicates a problem with the wired remote control or its connection to the indoor unit.