What does Weak airflow - Energy saving fan mean?

If 'Fan control for energy saving' is enabled, the indoor unit fan may temporarily stop during cooling operation to conserve energy, leading to weak or stopped airflow.

Common Causes

  • The energy-saving fan control feature is active on the unit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the remote controller settings for any active energy-saving fan control.

  2. 2

    Cancel the 'Fan control for energy saving' to restore normal fan operation.

  3. 3

    Refer to page 7 of the manual for instructions on how to cancel this function.