3-time blink 2.5 seconds OFF

3-time blink 2.5 seconds OFF — Discharge temperature overheat protection

Mitsubishi Electric · Air Conditioners

What does 3-time blink 2.5 seconds OFF mean?

The outdoor unit LED blinks 3 times with a 2.5-second pause. This indicates that the discharge temperature thermistor exceeded 116°C, causing the compressor to stop. The compressor can restart when the temperature drops below 100°C.

Common Causes

  • Refrigerant circuit issue
  • Incorrect refrigerant amount (too little or too much)
  • LEV (Linear Expansion Valve) malfunction

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure the outdoor unit is not obstructed by debris or plants, allowing proper airflow.

  2. 2

    Turn off the power to the unit at the circuit breaker, wait for 5-10 minutes for cooling, then restart.

  3. 3

    If the problem continues, a qualified technician should check the refrigerant circuit and refrigerant amount.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026

Related Faults

1-time blink (recall mode)Outdoor Unit Recall: 1-time blink - Indoor/outdoor communication, receiving error1-time blink 2.5 seconds OFF (Outdoor unit operates)1-time blink 2.5 seconds OFF — Frequency drop by current protection (Outdoor unit operates)1-time blink every 2.5 seconds1-time blink every 2.5 seconds — Outdoor unit overcurrent protection