CodeRegistry
Brands
  1. Home
  2. Mitsubishi Heavy Industries
  3. Air Conditioners
  4. 51
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

51

Current cut error — RUN LED flashes 5 times, TIMER LED flashes 1 time

Mitsubishi Heavy Industries · Air Conditioners

What does 51 mean?

The compressor has stopped due to a 'current cut', potentially after failing to start multiple times in succession. This suggests problems with compressor wiring, the power transistor, or the compressor itself.

Common Causes

  • Compressor start failure (multiple times)
  • Compressor wiring is disconnected or damaged
  • Damaged power transistor
  • Defective power source construction
  • Faulty outdoor PCB or compressor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the unit before inspecting.

  2. 2

    Inspect all compressor wiring connections to ensure they are secure, not disconnected, and free from damage.

  3. 3

    Verify the integrity of the power source construction supplying the unit.

  4. 4

    If connections and power appear sound, the power transistor, compressor, or outdoor PCB may be faulty and require professional assessment.

Browse all codes in this manual (110)
Verified technical data. Last updated: April 2026

Related Faults

01Power source faulty — RUN LED OFF, TIMER LED flashes 1 time05Wired remote control wiring error — RUN LED OFF, TIMER LED flashes 5 times35Cooling high pressure control activated — RUN LED flashes 3 times, TIMER LED flashes 5 times
Source: Mitsubishi Heavy Industries Air Conditioners
Open Manual (Page 53)Search more codes in this manual