82

Indoor heat exchanger sensor abnormal — RUN LED flashes 8 times, TIMER LED flashes 2 times

Mitsubishi Heavy Industries · Air Conditioners

What does 82 mean?

The indoor heat exchanger sensor is reporting abnormal readings, its wire is disconnected, broken, or short-circuited, leading to an anomalous stop of the unit.

Common Causes

  • Indoor heat exchanger sensor wire is disconnected or broken
  • Indoor heat exchanger sensor is short-circuited or faulty
  • Poor connector connections for the sensor
  • Faulty indoor PCB

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the unit.

  2. 2

    Locate the indoor heat exchanger sensor.

  3. 3

    Inspect the sensor wire for any visible disconnections, breakage, or signs of a short circuit.

  4. 4

    Check the connector connections for the sensor, ensuring they are securely plugged in and free from corrosion.

  5. 5

    Reconnect any loose wires or connectors firmly.