CodeRegistry
Brands
  1. Home
  2. Mitsubishi Heavy Industries
  3. Air Conditioners
  4. 87
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

87

Heating high pressure control activated — RUN LED flashes 8 times, TIMER LED flashes 7 times

Mitsubishi Heavy Industries · Air Conditioners

What does 87 mean?

The system's high-pressure control has activated during heating operation and caused the compressor to stop. This indicates issues with refrigerant levels, closed service valves, or inefficient heat exchange during heating.

Common Causes

  • Service valve is closed or partially obstructed
  • Refrigerant is insufficient or overcharged
  • Compressor lock or overload operation
  • Faulty outdoor heat exchanger sensor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure all service valves on the outdoor unit are fully open.

  2. 2

    Check the refrigerant level; it may be insufficient or overcharged, requiring adjustment by a technician.

  3. 3

    Verify the outdoor unit has good ventilation and is not experiencing overload operation during heating due to environmental factors or blockages.

  4. 4

    If the issue persists, the compressor may be locked or faulty, or the outdoor heat exchanger sensor could be malfunctioning.

Browse all codes in this manual (110)
Verified technical data. Last updated: April 2026

Related Faults

01Power source faulty — RUN LED OFF, TIMER LED flashes 1 time05Wired remote control wiring error — RUN LED OFF, TIMER LED flashes 5 times35Cooling high pressure control activated — RUN LED flashes 3 times, TIMER LED flashes 5 times
Source: Mitsubishi Heavy Industries Air Conditioners
Open Manual (Page 53)Search more codes in this manual