E35 / Remote Keeps Flashing

E35 / Remote Control Keeps Flashing - Cooling overload operation

Mitsubishi Heavy Industries · Air Conditioners

What does E35 / Remote Keeps Flashing mean?

The remote control keeps flashing (while the indoor unit's green LED keeps flashing and red LED stays off). This indicates the outdoor unit is experiencing an overload during cooling operation, specifically a higher outdoor heat exchanger temperature.

Common Causes

  • High outdoor heat exchanger temperature due to installation or operation status
  • A defective outdoor heat exchanger temperature sensor
  • A defective outdoor unit control PCB

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the outdoor unit for any obstructions blocking airflow (e.g., leaves, debris, overgrown plants).

  2. 2

    Clean the outdoor coil if it appears dirty.

  3. 3

    Reduce the cooling setting on your remote control and allow the unit to stabilize.

  4. 4

    If the problem persists, contact a service technician to inspect the outdoor heat exchanger temperature sensor or the control PCB.

Browse all codes in this manual (110)
Verified technical data. Last updated: April 2026

Related Faults

01Power source faulty — RUN LED OFF, TIMER LED flashes 1 time05Wired remote control wiring error — RUN LED OFF, TIMER LED flashes 5 times35Cooling high pressure control activated — RUN LED flashes 3 times, TIMER LED flashes 5 times
Source: Mitsubishi Heavy Industries Air Conditioners
Open Manual (Page 107)Search more codes in this manual