Alarm 291 - Recurring safety defr. (Recurring safety defrosting)

NIBE · S-Series Heat Pumps

What does 291 mean?

The Heat Pump has initiated 10 repeated defrosting cycles according to protection conditions. This indicates a persistent problem with ice formation or defrosting effectiveness.

Common Causes

  • Poor airflow, possibly due to leaves, snow, or ice blocking the outdoor unit.
  • Environmental conditions requiring frequent defrosting.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the outdoor unit for any blockages like leaves, snow, or ice on the fan, grille, or fan cone, and clear them.

  2. 2

    Activate the 'fan de-icing' function in your NIBE indoor module/control module. If the problem recurs, activate 'continuous fan de-icing'.

  3. 3

    Ensure that the air flow across the evaporator is correct and not restricted.

  4. 4

    If the problem persists despite clearing obstructions and using de-icing functions, contact a NIBE service technician.