Information message 523

Information message 523 — Low flow during defrost

NIBE · SMO 20 Control Module

What does Information message 523 mean?

The system detects insufficient water flow during a defrost cycle. The charging pump attempts to compensate by running at maximum speed. If the low flow persists, this message is displayed.

Common Causes

  • Insufficient water flow in the system during defrost.
  • Blocked filters or debris in the water circulation path.
  • Problem with the charging pump or its operation.
  • F2120 outdoor unit not meeting minimum firmware requirements (version 607).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the system's water filters for any blockages and clean them if necessary.

  2. 2

    Check the charging pump for proper operation; listen for unusual noises or signs of failure.

  3. 3

    Verify the F2120 outdoor unit has firmware version 607 or later.

  4. 4

    Update the NIBE SMO 20 firmware to the latest available version.

  5. 5

    If the issue continues, contact a service technician to diagnose the flow problem.