What does PV-inverter communication alarm mean?

The EME20 accessory reported a communication error with a PV-inverter, and this alarm would reappear even after being manually reset on the display. This indicates a persistent underlying communication issue.

Common Causes

  • Intermittent communication fault with the PV-inverter.
  • Software bug in EME20 causing alarms to re-trigger falsely.
  • Loose wiring or connection between EME20 and the PV-inverter.
  • Issue with the PV-inverter itself.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify all communication cables between the EME20 and the PV-inverter are securely connected.

  2. 2

    Check the PV-inverter's display or companion app for any specific error messages.

  3. 3

    Power cycle both the EME20 accessory and the PV-inverter.

  4. 4

    Update the NIBE SMO 20 firmware to version 8700R2 or later to prevent false re-triggering of the alarm.