This error indicates a problem with the DC Link, which manages the power supply to the air conditioning unit. It means there's either too much current or too low voltage detected.
Click steps to track your progress.
Check the main power connection to your air conditioning unit. Verify the input voltage meets requirements (e.g., 220Vac for single-phase, 380Vac for 3-phase).
Power off the unit at the main breaker, wait for a few minutes, then power it back on to see if the error clears.
Inspect all power wires and connections for tightness and correct joining. If multiple units are installed, ensure communication wires are not mixed with power connections.
Visually check the reactor and its connecting wires for any signs of damage, looseness, or improper connection to the Inverter PCB.
Examine the fuses on the EMI PBA for any signs of being blown or defective.
Ensure that all screws on the Terminal Block and Power Terminal Box are firmly fastened and wires are securely assembled.