E035

E035 — Double pump communication error

Wilo · Wilo-Stratos GIGA Pumps

What does E035 mean?

This error appears after connecting a double pump system that hasn't been pre-configured. Both pumps will run at an emergency speed.

Common Causes

  • Initial commissioning of a Y-pump installation without prior configuration
  • Double pump communication cable not connected properly

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Acknowledge the error message on the display.

  2. 2

    Ensure the "Access disable" is deactivated and service mode is active.

  3. 3

    Select one pump as the master by pressing the red button.

  4. 4

    Ensure the differential pressure sensor is connected to the master pump.

  5. 5

    Verify the measuring points for the differential pressure sensor are correctly placed on the system.